Abstract

Aims

Cardiac myosin-binding protein C (cMyC) demonstrated high diagnostic accuracy for the early detection of non-ST-elevation myocardial infarction (NSTEMI). Its dynamic release kinetics may enable a 0/1h-decision algorithm that is even more effective than the ESC hs-cTnT/I 0/1 h rule-in/rule-out algorithm.

Methods and results

In a prospective international diagnostic study enrolling patients presenting with suspected NSTEMI to the emergency department, cMyC was measured at presentation and after 1 h in a blinded fashion. Modelled on the ESC hs-cTnT/I 0/1h-algorithms, we derived a 0/1h-cMyC-algorithm. Final diagnosis of NSTEMI was centrally adjudicated according to the 4th Universal Definition of Myocardial Infarction. Among 1495 patients, the prevalence of NSTEMI was 17%. The optimal derived 0/1h-algorithm ruled-out NSTEMI with cMyC 0 h concentration below 10 ng/L (irrespective of chest pain onset) or 0 h cMyC concentrations below 18 ng/L and 0/1 h increase <4 ng/L. Rule-in occurred with 0 h cMyC concentrations of at least 140 ng/L or 0/1 h increase ≥15 ng/L. In the validation cohort (n = 663), the 0/1h-cMyC-algorithm classified 347 patients (52.3%) as ‘rule-out’, 122 (18.4%) as ‘rule-in’, and 194 (29.3%) as ‘observe’. Negative predictive value for NSTEMI was 99.6% [95% confidence interval (CI) 98.9–100%]; positive predictive value 71.1% (95% CI 63.1–79%). Direct comparison with the ESC hs-cTnT/I 0/1h-algorithms demonstrated comparable safety and even higher triage efficacy using the 0h-sample alone (48.1% vs. 21.2% for ESC hs-cTnT-0/1 h and 29.9% for ESC hs-cTnI-0/1 h; P < 0.001).

Conclusion

The cMyC 0/1h-algorithm provided excellent safety and identified a greater proportion of patients suitable for direct rule-out or rule-in based on a single measurement than the ESC 0/1h-algorithm using hs-cTnT/I.

Trial registration

ClinicalTrials.gov number, NCT00470587.

Key points Question: Could an algorithm employing cardiac myosin-binding protein C (cMyC) for triage of patients with chest pain accelerate rule-out and rule-in of myocardial infarction (MI)?

Findings: cMyC was able to triage a greater proportion of patients to early rule-out or rule-in of MI, while maintaining safety equivalent to hs-cTn-based algorithms (sensitivity ≥99%, negative predictive value ≥99.5% for rule-out).

Meaning: The use of cMyC instead or in addition to hs-cTnT/I could accelerate triage in the emergency department and potentially reduce length-of-stay by ruling-out more patients earlier.

Introduction

Rapid diagnosis is a prerequisite for the timely initiation of potentially life-saving treatment in patients presenting with suspected acute myocardial infarction (AMI). Equally, accurate diagnosis and rule-out of AMI avoids potential side-effects from overtreatment of patients not requiring potent anti-platelet and anti-thrombotic medication. With the intent of extending the substantial improvements made in the initial management and consequent mortality of patients presenting with ST-elevation MI (STEMI) to those with non-ST-elevation MI (NSTEMI)1; the biochemical detection and quantification of acute cardiomyocyte necrosis is key. For this reason, the European Society of Cardiology (ESC) recommends the clinical use of rapid triage algorithms based on high-sensitivity cardiac troponin (hs-cTn) T/I concentrations.2 The ESC hs-cTnT/I 0/1h-algorithms rapidly rule-out and/or rule-in NSTEMI in patients presenting with acute chest discomfort to the emergency department (ED).2 This approach was made possible by the development and extensive clinical validation of hs-cTnT/I assays, which allow the detection and quantification of small amounts of cardiomyocyte necrosis.3–8

Recent real-world findings suggested that the clinical use of the ESC hs-cTnT 0/1h-algorithm is feasible, very safe, and associated with a substantially reduced time to ED discharge as compared to other algorithms including the ESC 0/3h-algorithm.6,8–10 However, even the most recently published ESC hs-cTnT/I 0/1h-algorithms provide opportunities for further improvements, e.g. by increasing the triage decisions that can be made on the immediate, 0 h, blood draw. Use of a more abundant, even more rapidly released biomarker, which is still a cardiac-restricted protein, such as cardiac myosin-binding protein C (cMyC); could potentially further improve the efficacy towards rule-out and/or rule-in.11–16

We, therefore, aimed to (i) derive and validate a 0/1h cMyC-algorithm to rapidly rule-out or rule-in NSTEMI, (ii) directly compare this to the well-established ESC hs-cTnT/I 0/1h-algorithms, and (iii) evaluate the incremental value of a dual marker approach integrating 0h-cMyC criteria into the established ESC hs-cTnT/I 0/1h-algorithms.

Methods

In a prospective international diagnostic study enrolling patients presenting with suspected NSTEMI to the ED, venous blood samples were drawn at presentation (0 h) and after 1 h were measured for cMyC, hs-cTnT, and hs-cTnI.

Study design and population

Advantageous Predictors of Acute Coronary Syndrome Evaluation (APACE) was a prospective international multicentre diagnostic study designed to advance the early diagnosis of NSTEMI.17–20 Adult patients presenting to the ED with acute chest discomfort possibly indicating NSTEMI were eligible for recruitment if the onset, or peak chest pain symptoms were within the preceding 12 h. Enrolment was independent of renal function, while patients with terminal kidney failure on chronic dialysis were excluded. For this analysis, the following patients were excluded: patients presenting with STEMI; patients with missing concentrations of cMyC at presentation or 1 h, and patients in whom the final diagnosis remained unclear after adjudication and at least one hs-cTnT level was elevated. A small proportion of patients did not have cMyC concentrations measured at presentation or 1h-repeat due to insufficient sample volume; baseline characteristics of patients with vs. without available cMyC measurements were comparable and are listed in Supplementary material online, Table S1. The protocol used for routine clinical assessment during patient enrolment has been described previously.16 The study was carried out according to the principles of the Declaration of Helsinki and approved by the local ethics committees. Written informed consent was obtained from all patients. T.K., R.T., T.N., J.B., P.A., M.R., K.W., and C.M. had full access to all the data in the study and take responsibility for its integrity and the data analysis. The authors designed the study, gathered, and analysed the data according to the STARD guidelines (Supplementary material online, Table S1) for studies of diagnostic accuracy, vouched for the data and analysis, wrote the paper, and decided to submit for publication.

Adjudicated final diagnosis

Adjudication of the final diagnosis was performed centrally by two independent cardiologists according to the universal definition of MI using all available clinical information including cardiac imaging, serial hs-cTnT measurements, but blinded to cMyC.21 Two sets of data were used: first, all clinical data derived from routine clinical investigations including all available medical records—patient history, physical examination, results of laboratory testing including serial local (h)s-cTn, radiologic testing, ECG, echocardiography, cardiac exercise stress test, lesion severity, and morphology at coronary angiography—pertaining to the patient from the time of ED presentation to 90-day follow-up. Second, a study-specific assessment was collected, including 34 chest pain characteristics and serial hs-cTnT measurements to take advantage of the higher sensitivity and higher overall diagnostic accuracy offered by the more sensitive assays, as previously published.7,17 In situations of disagreement about the diagnosis, cases were reviewed and adjudicated in conjunction with a third cardiologist. In brief, NSTEMI was diagnosed when there was evidence of myocardial necrosis in association with a clinical setting consistent with myocardial ischaemia. Myocardial necrosis was diagnosed by at least one (h)s-cTn value above the 99th percentile together with a significant rise and/or fall. All other patients were classified into the categories of unstable angina (UA), cardiac non-coronary disease (e.g. tachyarrhythmias, perimyocarditis), non-cardiac chest pain, and symptoms of unknown origin. For follow-up and clinical endpoints, see Supplementary material online.

Measurement of cMyC, hs-cTnT, and hs-cTnI

Blood samples for determination of cMyC, hs-cTnI, and hs-cTnT were collected into heparin plasma and serum tubes at presentation to the ED and serially thereafter (at time points 1 h, 2 h, 3 h, and 6 h). Serial sampling was discontinued when a diagnosis of NSTEMI was certain and treatment required patient transfer to the coronary care unit or catheter laboratory. After centrifugation, samples were frozen at −80°C until they were assayed in a blinded fashion in a dedicated core laboratory. cMyC was measured using the previously established, pre-commercial high-sensitivity assay on the Singulex Erenna platform that was performed by EMD Merck Millipore (Hayward, CA, USA).22 The assay has a lower limit of detection (LoD) of 0.4 ng/L and a lower limit of quantification (LoQ) of 1.2 ng/L with a ≤20% coefficient of variation at LoQ, ≤10% CV above 4.6 ng/L and, specifically, at 99th centile. For further details, please see Supplementary material online.

Derivation and validation of the cMyC 0/1h-algorithm

The cMyC 0/1h-algorithm was developed in a derivation and validation design (random 1:1 split in cohort of patients with all biomarkers available; Supplementary material online, Figure S1). The concept of the cMyC 0/1h-algorithm was comparable to the ESC hs-cTnT/I 0/1h-algorithm (as per 2020 ESC guidelines2) as it allowed the rapid triage of patients with suspected NSTEMI towards rule-out, observe and rule-in based on cMyC concentrations obtained at presentation (0 h) and after 1 h (Supplementary material online, Figure S2). However, it differed in two important details: first, while the ESC hs-cTnT/I 0/1h-algorithm does not allow for direct rule-out based on a single hs-cTnT measurement in patients presenting very early (≤3 h) after chest pain onset due to concerns of delayed release of hs-cTnT/I in NSTEMI,23 the cMyC 0/1h-algorithm offered a direct rule-out option based on a single measurement irrespective of the time since chest pain onset (based on prior research describing an earlier rise and shorter time-to-peak concentration11,13,16) as well as favourable pilot data in patients presenting very early (≤3 h) after chest pain onset.24 Second, the ESC hs-cTnT/I 0/1h-algorithm considered dynamic changes as absolute, unsigned changes (not differentiating between rise or fall) between the 0h- and 1h-sample, whereas the cMyC 0/1h-algorithm considers absolute, signed changes (differentiating between rise or fall; based on prior insights into the release kinetics of cMyC).11,13

We derived and selected a cut-off combination fulfilling the pre-defined performance targets [negative predictive value (NPV) ≥99%, sensitivity ≥99% positive predictive value (PPV) ≥70%] in the derivation dataset. This particular cut-off combination was then applied to the validation dataset to test its performance. Prior publications have evaluated the cut-off concentrations in the presentation samples only.16,24 For integration of cMyC into ESC algorithms, see Supplementary material online.

Statistical analysis

All data were expressed as medians [1st quartile; 3rd quartile] or means (standard deviation) for continuous variables (compared with the Mann–Whitney U test or Student’s t-test, respectively), and for categorical variables as numbers and percentages (compared with Pearson χ2). Hypothesis testing was two-tailed, and P values <0.05 were considered statistically significant. No adjustment for multiple comparisons was performed.

Rule-out safety of the 0/1h-algorithm was quantified by the NPV, sensitivity, and likelihood ratio (LR) for NSTEMI in the rule-out group. Accuracy of rule-in was quantified by the PPV, specificity, and LR for NSTEMI in the rule-in group. NPV and PPV were derived using the Bayes theorem and Jeffreys prior. Efficacy was quantified by the proportion of patients triaged to either rule-out or rule-in. Subgroup analyses were performed for patients presenting early (chest pain onset ≤3 h prior to ED presentation); as well as stratified by age groups, sex, and presence of renal disease.

Confidence intervals (CIs) of proportions, where appropriate, were computed using Wilson’s method. The McNemar test was used to compare sensitivity and specificity; NPV and PPV were compared using weighted generalized score statistics within the R package DTComPair.25

All statistical analyses were performed using R, version 3.6.1 (The R Foundation for Statistical Computing).

Results

Baseline demographics

Of 1495 patients with available cMyC measurements, 1326 had hs-cTnT, hs-cTnI, and cMyC results available at 0 h and 1 h (Supplementary material online, Figure S1). NSTEMI was the final diagnosis in 17%. Across the entire cohort, median age was 62 years [50; 75], 31% of patients were women and 37% had a prior history of CAD (Table 1, Supplementary material online, Table S2). Concentrations of cMyC, hs-cTnT, and hs-cTnI at 0 h and 1 h and absolute 0/1h-changes were significantly higher in NSTEMI compared to other causes of chest discomfort (Supplementary material online, Table S3 and Figures S3 and S4).

Table 1

Baseline demographics

DemographicsAll patients (N = 1495)No NSTEMI (N = 1236)NSTEMI (N = 259)P valuea
Adjudicated NSTEMI259 (17%)0 (0%)259 (100%)NA
Female sex464 (31%)403 (33%)61 (24%)0.005
Age, years62 [50; 75]61 [49; 73]72 [59; 80]<0.001
Medical history
 Hypertension943 (63%)743 (60%)200 (77%)<0.001
 Hyperlipidaemia779 (52%)610 (49%)169 (65%)<0.001
 Diabetes mellitus286 (19%)211 (17%)75 (29%)<0.001
 Current smoking361 (24%)292 (24%)69 (27%)0.341
 History of smoking560 (37%)448 (36%)112 (43%)0.041
 Previous revascularization (PCI or CABG)430 (29%)333 (27%)97 (37%)0.001
 Coronary artery disease547 (37%)414 (33%)133 (51%)<0.001
Vital parameters
 Heart rate, b.p.m.76 [66; 89]75 [65; 89]78 [69; 90]0.027
 Systolic blood pressure, mmHg142 [126; 160]142 [127; 159]142 [126; 161]0.592
 Diastolic blood pressure, mmHg82 [72; 92]83 [72; 92]80 [70; 91]0.130
Laboratory results
 Estimated glomerular filtration rate, mL/min/1.73 m2b85 [68; 101]86 [70; 102]73 [56; 95]<0.001
 cMyC 0 h, ng/L16 [8; 49]13 [7; 28]211 [58; 689]<0.001
 cMyC 1h-change, ng/Lc0 [−2; 4]0 [−2; 2]33 [1; 145]<0.001
 hs-cTnT 0 h, ng/L9 [5; 20]7 [5; 13]58 [26; 119]<0.001
 hs-cTnT 1h-change, ng/Ld1 [0; 2]0 [0; 1]8 [3; 22]<0.001
 hs-cTnI 0 h, ng/L5 [2; 14]4 [2; 8]84 [18; 389]<0.001
 hs-cTnI 1h-change, ng/Ld1 [0; 2]0 [0; 1]27 [6; 124]<0.001
DemographicsAll patients (N = 1495)No NSTEMI (N = 1236)NSTEMI (N = 259)P valuea
Adjudicated NSTEMI259 (17%)0 (0%)259 (100%)NA
Female sex464 (31%)403 (33%)61 (24%)0.005
Age, years62 [50; 75]61 [49; 73]72 [59; 80]<0.001
Medical history
 Hypertension943 (63%)743 (60%)200 (77%)<0.001
 Hyperlipidaemia779 (52%)610 (49%)169 (65%)<0.001
 Diabetes mellitus286 (19%)211 (17%)75 (29%)<0.001
 Current smoking361 (24%)292 (24%)69 (27%)0.341
 History of smoking560 (37%)448 (36%)112 (43%)0.041
 Previous revascularization (PCI or CABG)430 (29%)333 (27%)97 (37%)0.001
 Coronary artery disease547 (37%)414 (33%)133 (51%)<0.001
Vital parameters
 Heart rate, b.p.m.76 [66; 89]75 [65; 89]78 [69; 90]0.027
 Systolic blood pressure, mmHg142 [126; 160]142 [127; 159]142 [126; 161]0.592
 Diastolic blood pressure, mmHg82 [72; 92]83 [72; 92]80 [70; 91]0.130
Laboratory results
 Estimated glomerular filtration rate, mL/min/1.73 m2b85 [68; 101]86 [70; 102]73 [56; 95]<0.001
 cMyC 0 h, ng/L16 [8; 49]13 [7; 28]211 [58; 689]<0.001
 cMyC 1h-change, ng/Lc0 [−2; 4]0 [−2; 2]33 [1; 145]<0.001
 hs-cTnT 0 h, ng/L9 [5; 20]7 [5; 13]58 [26; 119]<0.001
 hs-cTnT 1h-change, ng/Ld1 [0; 2]0 [0; 1]8 [3; 22]<0.001
 hs-cTnI 0 h, ng/L5 [2; 14]4 [2; 8]84 [18; 389]<0.001
 hs-cTnI 1h-change, ng/Ld1 [0; 2]0 [0; 1]27 [6; 124]<0.001

Data are expressed as medians [1st quartile, 3rd quartile] or mean ± standard deviation, for categorical variables as n (%).

CABG, coronary artery bypass graft; IQR, interquartile range; NSTEMI, non-ST-segment elevation myocardial infarction as per gold-standard adjudication; PCI, percutaneous coronary intervention.

a

P values for comparison NSTEMI group vs. no NSTEMI.

b

Glomerular filtration rate was estimated using the modification of diet in renal disease (MDRD) formula.

c

cMyC deltas are calculated as the signed value (differentiating between rise or fall).

d

hs-cTn deltas are calculated as the unsigned value.

Table 1

Baseline demographics

DemographicsAll patients (N = 1495)No NSTEMI (N = 1236)NSTEMI (N = 259)P valuea
Adjudicated NSTEMI259 (17%)0 (0%)259 (100%)NA
Female sex464 (31%)403 (33%)61 (24%)0.005
Age, years62 [50; 75]61 [49; 73]72 [59; 80]<0.001
Medical history
 Hypertension943 (63%)743 (60%)200 (77%)<0.001
 Hyperlipidaemia779 (52%)610 (49%)169 (65%)<0.001
 Diabetes mellitus286 (19%)211 (17%)75 (29%)<0.001
 Current smoking361 (24%)292 (24%)69 (27%)0.341
 History of smoking560 (37%)448 (36%)112 (43%)0.041
 Previous revascularization (PCI or CABG)430 (29%)333 (27%)97 (37%)0.001
 Coronary artery disease547 (37%)414 (33%)133 (51%)<0.001
Vital parameters
 Heart rate, b.p.m.76 [66; 89]75 [65; 89]78 [69; 90]0.027
 Systolic blood pressure, mmHg142 [126; 160]142 [127; 159]142 [126; 161]0.592
 Diastolic blood pressure, mmHg82 [72; 92]83 [72; 92]80 [70; 91]0.130
Laboratory results
 Estimated glomerular filtration rate, mL/min/1.73 m2b85 [68; 101]86 [70; 102]73 [56; 95]<0.001
 cMyC 0 h, ng/L16 [8; 49]13 [7; 28]211 [58; 689]<0.001
 cMyC 1h-change, ng/Lc0 [−2; 4]0 [−2; 2]33 [1; 145]<0.001
 hs-cTnT 0 h, ng/L9 [5; 20]7 [5; 13]58 [26; 119]<0.001
 hs-cTnT 1h-change, ng/Ld1 [0; 2]0 [0; 1]8 [3; 22]<0.001
 hs-cTnI 0 h, ng/L5 [2; 14]4 [2; 8]84 [18; 389]<0.001
 hs-cTnI 1h-change, ng/Ld1 [0; 2]0 [0; 1]27 [6; 124]<0.001
DemographicsAll patients (N = 1495)No NSTEMI (N = 1236)NSTEMI (N = 259)P valuea
Adjudicated NSTEMI259 (17%)0 (0%)259 (100%)NA
Female sex464 (31%)403 (33%)61 (24%)0.005
Age, years62 [50; 75]61 [49; 73]72 [59; 80]<0.001
Medical history
 Hypertension943 (63%)743 (60%)200 (77%)<0.001
 Hyperlipidaemia779 (52%)610 (49%)169 (65%)<0.001
 Diabetes mellitus286 (19%)211 (17%)75 (29%)<0.001
 Current smoking361 (24%)292 (24%)69 (27%)0.341
 History of smoking560 (37%)448 (36%)112 (43%)0.041
 Previous revascularization (PCI or CABG)430 (29%)333 (27%)97 (37%)0.001
 Coronary artery disease547 (37%)414 (33%)133 (51%)<0.001
Vital parameters
 Heart rate, b.p.m.76 [66; 89]75 [65; 89]78 [69; 90]0.027
 Systolic blood pressure, mmHg142 [126; 160]142 [127; 159]142 [126; 161]0.592
 Diastolic blood pressure, mmHg82 [72; 92]83 [72; 92]80 [70; 91]0.130
Laboratory results
 Estimated glomerular filtration rate, mL/min/1.73 m2b85 [68; 101]86 [70; 102]73 [56; 95]<0.001
 cMyC 0 h, ng/L16 [8; 49]13 [7; 28]211 [58; 689]<0.001
 cMyC 1h-change, ng/Lc0 [−2; 4]0 [−2; 2]33 [1; 145]<0.001
 hs-cTnT 0 h, ng/L9 [5; 20]7 [5; 13]58 [26; 119]<0.001
 hs-cTnT 1h-change, ng/Ld1 [0; 2]0 [0; 1]8 [3; 22]<0.001
 hs-cTnI 0 h, ng/L5 [2; 14]4 [2; 8]84 [18; 389]<0.001
 hs-cTnI 1h-change, ng/Ld1 [0; 2]0 [0; 1]27 [6; 124]<0.001

Data are expressed as medians [1st quartile, 3rd quartile] or mean ± standard deviation, for categorical variables as n (%).

CABG, coronary artery bypass graft; IQR, interquartile range; NSTEMI, non-ST-segment elevation myocardial infarction as per gold-standard adjudication; PCI, percutaneous coronary intervention.

a

P values for comparison NSTEMI group vs. no NSTEMI.

b

Glomerular filtration rate was estimated using the modification of diet in renal disease (MDRD) formula.

c

cMyC deltas are calculated as the signed value (differentiating between rise or fall).

d

hs-cTn deltas are calculated as the unsigned value.

Derivation of the cMyC 0/1h-algorithm

The optimal derived cMyC 0/1h-algorithm ruled-out NSTEMI with 0 h concentrations below 10 ng/L (irrespective of chest pain onset) or 0 h cMyC concentrations below 18 ng/L and a 0/1 h increase of <4 ng/L (Supplementary material online, Figure S2). Triage towards rule-in occurred with 0 h cMyC concentrations of at least 140 ng/L or a 0/1 h increase of at least 15 ng/L. Applying the 0/1 h cMyC-algorithm in the derivation cohort (n = 663), 325 patients (49.0%) could be classified as ‘rule-out’, 123 patients (18.6%) as ‘rule-in’, and 215 patients (32.4%) as ‘observe’ within 1 h. The NPV for NSTEMI in the rule-out group was 99.5% (95% CI 98.0–100), sensitivity was 99.1% (95% CI 97–100), and the PPV for NSTEMI in the rule-in group was 70.6% (95% CI 62.5–78.4; Supplementary material online, Table S4).

Validation of the cMyC 0/1h-algorithm

Applying the derived cMyC 0/1h-algorithm in the validation cohort (n = 663, 91 NSTEMI), 36.2% (240) of patients could be ruled-out directly at presentation (based on 0h-sample only), and 52.3% (347) after the completed 0/1h-algorithm (Figure 2). Rule-out safety was very high and met the predefined target with an NPV of 99.6% (95% CI 98.9–100) and a sensitivity of 99.1% (95% CI 97–100; Table 2 incl. performance in early presenters; misclassified patients see Supplementary material online, Table S5). There were no false-negatives amongst the subset of patients presenting within 3 h of chest pain onset (n = 250).

Table 2

Algorithm performance

cMyC 0/1h-algorithmESC hs-cTnT 0/1h-algorithmPaESC hs-cTnI 0/1h-algorithmPa
Prevalence of NSTEMI17% (same cohort)
 NPV
  • 99.57% (98.88–100)

  • EP: 100% (97.23–1)

99.87% (99.51–100)0.31799.56% (98.85–100)0.714
 Sensitivity
  • 99.06% (97–100)

  • EP: 100% (91.97–1)

100% (100–100)0.31799.12% (97.03–100)1.000
 PPV
  • 71.14% (63.1–78.99)

  • EP: 70.6% (57–81.29)

78.88% (71.4–86.08)0.02272.27% (64.47–79.86)0.714
 Specificity
  • 93.6% (91.37–95.61)

  • EP: 92.7% (88.33–95.54)

95.67% (93.85–97.26)0.03493.64% (91.52–95.67)1.000
 LR+11.97 (8.77–17.46)18.26 (12.62–28.75)12.66 (9.29–18.32)
 LR−0.01 (0–0.03)0 (0–0.02)0.01 (0–0.03)
Proportion ruled-out
 Based on 0-h sample240 (36.2%)72 (10.9%)<0.001125 (18.9%)<0.001
 Based on 0/1-h samples347 (52.3%)390 (58.8%)0.020341 (51.4%)0.784
Proportion ruled-in
 Based on 0-h sample79 (11.9%)68 (10.3%)0.38273 (11%)0.666
 Based on 0/1-h samples122 (18.4%)115 (17.4%)0.667127 (19.2%)0.778
Overall efficacy
 Based on 0-h sample319 (48.1%)140 (21.1%)<0.001198 (29.9%)<0.001
 Based on 0/1-h samples469 (70.7%)505 (76.2%)0.030468 (70.6%)0.904
 Prevalence of NSTEMI in observational group26 (13.4%)23 (14.6%)0.87621 (10.8%)0.522
cMyC 0/1h-algorithmESC hs-cTnT 0/1h-algorithmPaESC hs-cTnI 0/1h-algorithmPa
Prevalence of NSTEMI17% (same cohort)
 NPV
  • 99.57% (98.88–100)

  • EP: 100% (97.23–1)

99.87% (99.51–100)0.31799.56% (98.85–100)0.714
 Sensitivity
  • 99.06% (97–100)

  • EP: 100% (91.97–1)

100% (100–100)0.31799.12% (97.03–100)1.000
 PPV
  • 71.14% (63.1–78.99)

  • EP: 70.6% (57–81.29)

78.88% (71.4–86.08)0.02272.27% (64.47–79.86)0.714
 Specificity
  • 93.6% (91.37–95.61)

  • EP: 92.7% (88.33–95.54)

95.67% (93.85–97.26)0.03493.64% (91.52–95.67)1.000
 LR+11.97 (8.77–17.46)18.26 (12.62–28.75)12.66 (9.29–18.32)
 LR−0.01 (0–0.03)0 (0–0.02)0.01 (0–0.03)
Proportion ruled-out
 Based on 0-h sample240 (36.2%)72 (10.9%)<0.001125 (18.9%)<0.001
 Based on 0/1-h samples347 (52.3%)390 (58.8%)0.020341 (51.4%)0.784
Proportion ruled-in
 Based on 0-h sample79 (11.9%)68 (10.3%)0.38273 (11%)0.666
 Based on 0/1-h samples122 (18.4%)115 (17.4%)0.667127 (19.2%)0.778
Overall efficacy
 Based on 0-h sample319 (48.1%)140 (21.1%)<0.001198 (29.9%)<0.001
 Based on 0/1-h samples469 (70.7%)505 (76.2%)0.030468 (70.6%)0.904
 Prevalence of NSTEMI in observational group26 (13.4%)23 (14.6%)0.87621 (10.8%)0.522

Direct comparison of the performance of the cMyC 0/1h-algorithm to the established ESC hs-cTnT/I 0/1h-algorithms in the validation cohort (n = 663).

EP, early presenters; LR+, positive likelihood ratio; LR−, negative likelihood ratio; NPV, negative predictive value; NSTEMI, non-ST-elevation myocardial infarction; PPV, positive predictive value.

a

P values for comparison cMyC to hs-cTn.

Table 2

Algorithm performance

cMyC 0/1h-algorithmESC hs-cTnT 0/1h-algorithmPaESC hs-cTnI 0/1h-algorithmPa
Prevalence of NSTEMI17% (same cohort)
 NPV
  • 99.57% (98.88–100)

  • EP: 100% (97.23–1)

99.87% (99.51–100)0.31799.56% (98.85–100)0.714
 Sensitivity
  • 99.06% (97–100)

  • EP: 100% (91.97–1)

100% (100–100)0.31799.12% (97.03–100)1.000
 PPV
  • 71.14% (63.1–78.99)

  • EP: 70.6% (57–81.29)

78.88% (71.4–86.08)0.02272.27% (64.47–79.86)0.714
 Specificity
  • 93.6% (91.37–95.61)

  • EP: 92.7% (88.33–95.54)

95.67% (93.85–97.26)0.03493.64% (91.52–95.67)1.000
 LR+11.97 (8.77–17.46)18.26 (12.62–28.75)12.66 (9.29–18.32)
 LR−0.01 (0–0.03)0 (0–0.02)0.01 (0–0.03)
Proportion ruled-out
 Based on 0-h sample240 (36.2%)72 (10.9%)<0.001125 (18.9%)<0.001
 Based on 0/1-h samples347 (52.3%)390 (58.8%)0.020341 (51.4%)0.784
Proportion ruled-in
 Based on 0-h sample79 (11.9%)68 (10.3%)0.38273 (11%)0.666
 Based on 0/1-h samples122 (18.4%)115 (17.4%)0.667127 (19.2%)0.778
Overall efficacy
 Based on 0-h sample319 (48.1%)140 (21.1%)<0.001198 (29.9%)<0.001
 Based on 0/1-h samples469 (70.7%)505 (76.2%)0.030468 (70.6%)0.904
 Prevalence of NSTEMI in observational group26 (13.4%)23 (14.6%)0.87621 (10.8%)0.522
cMyC 0/1h-algorithmESC hs-cTnT 0/1h-algorithmPaESC hs-cTnI 0/1h-algorithmPa
Prevalence of NSTEMI17% (same cohort)
 NPV
  • 99.57% (98.88–100)

  • EP: 100% (97.23–1)

99.87% (99.51–100)0.31799.56% (98.85–100)0.714
 Sensitivity
  • 99.06% (97–100)

  • EP: 100% (91.97–1)

100% (100–100)0.31799.12% (97.03–100)1.000
 PPV
  • 71.14% (63.1–78.99)

  • EP: 70.6% (57–81.29)

78.88% (71.4–86.08)0.02272.27% (64.47–79.86)0.714
 Specificity
  • 93.6% (91.37–95.61)

  • EP: 92.7% (88.33–95.54)

95.67% (93.85–97.26)0.03493.64% (91.52–95.67)1.000
 LR+11.97 (8.77–17.46)18.26 (12.62–28.75)12.66 (9.29–18.32)
 LR−0.01 (0–0.03)0 (0–0.02)0.01 (0–0.03)
Proportion ruled-out
 Based on 0-h sample240 (36.2%)72 (10.9%)<0.001125 (18.9%)<0.001
 Based on 0/1-h samples347 (52.3%)390 (58.8%)0.020341 (51.4%)0.784
Proportion ruled-in
 Based on 0-h sample79 (11.9%)68 (10.3%)0.38273 (11%)0.666
 Based on 0/1-h samples122 (18.4%)115 (17.4%)0.667127 (19.2%)0.778
Overall efficacy
 Based on 0-h sample319 (48.1%)140 (21.1%)<0.001198 (29.9%)<0.001
 Based on 0/1-h samples469 (70.7%)505 (76.2%)0.030468 (70.6%)0.904
 Prevalence of NSTEMI in observational group26 (13.4%)23 (14.6%)0.87621 (10.8%)0.522

Direct comparison of the performance of the cMyC 0/1h-algorithm to the established ESC hs-cTnT/I 0/1h-algorithms in the validation cohort (n = 663).

EP, early presenters; LR+, positive likelihood ratio; LR−, negative likelihood ratio; NPV, negative predictive value; NSTEMI, non-ST-elevation myocardial infarction; PPV, positive predictive value.

a

P values for comparison cMyC to hs-cTn.

The cMyC 0/1h-algorithm classified 11.9% of patients as direct rule-in at 0 h, and 18.4% as rule-in after the completed algorithm. Accuracy was high and met the predefined target with a PPV of 71.1% (95% CI 63.1–79.0) and a specificity of 93.6% (95% CI 91.4–95.6). Overall, the cMyC 0/1h-algorithm assigned 70.7% of patients to either rule-out or rule-in categories, with 29.3% remaining in the observe zone with an NSTEMI prevalence of 13.4%.

Direct comparison of the cMyC 0/1h-algorithm with the ESC hs-cTnT/I 0/1h-algorithms

Overall, the performance of the cMyC 0/1h-algorithm was comparable to the ESC hs-cTnT/I 0/1h-algorithms (Table 2 and Figure 1). Of note, the cMyC 0/1h-algorithm was more effective at direct rule-out based on the 0h-sample alone (cMyC 36.2% direct rule-out vs. 10.9% with hs-cTnT; vs. 18.9% with hs-cTnI; P < 0.001 both) and more effective at either direct rule-out or rule-in based on the 0h-sample alone (48.1% vs. 21.2% for ESC hs-cTnT-0/1 h and 29.9% for ESC hs-cTnI-0/1 h, both P < 0.001), but not after a completed 0/1h-algorithm [cMyC overall efficacy 70.7% vs. 76.2% with hs-cTnT (P = 0.03) and 70.6% with hs-cTnI [P = 0.904]). Predefined subgroup analysis confirmed the consistency of these findings (Supplementary material online, Tables S6–S12 and Figure S5).

Comparison of cMyC and ESC hs-TnT/I 0/1h-algorithms: direct comparison of patient distribution in the validation cohort according to the cMyC 0/1h-algorithm and the ESC hs-cTnT/I 0/1h-algorithms. Final clinical adjudication of NSTEMI included hs-cTnT.
Figure 1

Comparison of cMyC and ESC hs-TnT/I 0/1h-algorithms: direct comparison of patient distribution in the validation cohort according to the cMyC 0/1h-algorithm and the ESC hs-cTnT/I 0/1h-algorithms. Final clinical adjudication of NSTEMI included hs-cTnT.

Integrating 0h-cMyC criteria into the established ESC hs-cTnT/I 0/1h-algorithms

Given the higher proportion of patients triaged towards rule-out with the 0h-cMyC criteria, the performance of a modified ESC hs-cTnT/I 0/1h-algorithms—using cMyC as an additional direct rule-out/rule-in criteria—was evaluated (Figure 2). This modified algorithm yielded comparable safety to the ESC hs-cTnT 0/1h-algorithm (NPV 99.9% both; sensitivity 100% both) but was inferior in terms of PPV (75.6% vs. 78.9%, P = 0.038) and specificity (94.6% vs. 95.6%, P = 0.014; Supplementary material online, Figure S6). There was no significant difference when comparing NPV, PPV, sensitivity, and specificity to the ESC hs-cTnI 0/1h-algorithm (Supplementary material online, Figure S7).

Dual-marker strategy: Concept outlining how the 0h cMyC concentration could be employed as a triage-booster when integrated into the established ESC 0/1h-algorithm.
Figure 2

Dual-marker strategy: Concept outlining how the 0h cMyC concentration could be employed as a triage-booster when integrated into the established ESC 0/1h-algorithm.

By adding the 0h-cMyC criteria to the triage process, the proportion of patients ruled-out and overall efficacy based on the 0-h samples was significantly increased: hs-cTnT + cMyC directly ruled-out 38.5% vs. 10.9% of patients for hs-cTnT alone (P < 0.001), overall efficacy at 0 h 51.7% vs. 21.1% (P < 0.001); hs-cTnI + cMyC direct rule-out 41.9% vs. 18.9% (P < 0.001), overall efficacy at 0 h 55.8% vs. 29.9% (P < 0.001; Supplementary material online, Figures S6 and S7 and Tables S13 and S14).

Prognostic utility for death at 30 days and 1 year

Beyond its diagnostic utility, the cMyC 0/1h-algorithm clearly delineates patients at varying degrees of risk of future events—Figure 3demonstrates a mortality plot stratified by triage category at 30-day and 1-year follow-up. Corresponding mortality data for hs-cTnT/I have been published before,16 but mortality plots have been reproduced to allow comparison (see Supplementary material online, Figures S8 and S9).

Mortality plot: cumulative event plot for the cMyC 0/1h-algorithm, with statistical comparison of event curves at 30 and 365 days with the log-rank tests; table displays number-at-risk and absolute number of events.
Figure 3

Mortality plot: cumulative event plot for the cMyC 0/1h-algorithm, with statistical comparison of event curves at 30 and 365 days with the log-rank tests; table displays number-at-risk and absolute number of events.

Discussion

This international multicentre study used central adjudication of the final diagnosis according to the fourth universal definition of MI and a derivation-validation design to contribute to a better understanding of the best possible clinical use of cMyC, a structural protein unique to cardiomyocytes that is more abundant and more rapidly released as compared to hs-cTnT/I.11–16,26 We report six major findings.

First, using the established concept of combining concentrations at ED presentation and absolute changes within 1 h, we were able to derive a cMyC 0/1h-algorithm achieving the predefined criteria of a NPV and sensitivity of at least 99% in the rule-out group and a PPV of at least 70% in the rule-in group in the validation cohort. Second, this algorithm enabled triage of three out of four patients with suspected NSTEMI based on the 0h and the 1h-sample. Third, the performance of the cMyC 0/1h-algorithm was comparable to that of the ESC hs-cTnT/I 0/1h-algorithms. Fourth, as an important differentiating feature, the cMyC 0/1h-algorithm triaged a substantially higher proportion of patients—an absolute increase of more than 25%—towards rule-out or rule-in based on the 0h-concentration alone. While this improvement diminishes after a completed 0/1h-algorithm, this ‘first shot’ benefit was at least in part due to a simplification of the single measurement rule-out pathway, which can be applied irrespective of the time interval from chest pain onset to ED presentation. In contrast, the single measurement rule-out pathway of the ESC hs-cTnT/I 0/1h-algorithms can only be applied in patients presenting 3 h or longer after chest pain onset. This differentiating feature might have allowed the algorithm to calibrate more closely to final outcomes, as the rapid release of cMyC following myocardial injury reduces the time to diagnosis by abolishing the need for repeat testing—rather than the biomarker exhibiting substantially different performance with respect to sensitivity and specificity. Fifth, similarly, integrating an alternative (‘or’) 0h-cMyC criteria into the established ESC hs-cTnT/I 0/1h-algorithms substantially increased (absolute increase of about 30%) the proportion of patients eligible for triage with the 0h-criteria. Sixth, beyond its diagnostic utility, the cMyC 0/1h-algorithm also accurately predicted all-cause mortality at 30 days and 1 year.

These findings extend and corroborate previous experimental and clinical studies on cMyC as a potential addition, or even alternative, to hs-cTnT/I in the early diagnosis of AMI.11–16,27 Pilot invivo studies have confirmed experimental studies that cMyC seems to be more rapidly released from injured cardiomyocytes in NSTEMI as compared to hs-cTnT/I.13 Among 1954 patients presenting with suspected AMI to the ED, discriminatory power for AMI, as quantified by the area under the receiver-operating characteristic curve (AUC), was comparable for cMyC (AUC, 0.924), hs-cTnT (AUC, 0.927), and hs-cTnI (AUC, 0.922) and superior to cTnI measured by a contemporary sensitivity assay (AUC, 0.909).16 The combination of cMyC with hs-cTnT or standard-sensitivity cTnI (but not hs-cTnI) led to an increase in AUC.

Increasing the proportion of patients eligible for safe rule-out of NSTEMI and possible early discharge from the ED using the 0h-cMyC criteria may have important medical and economic value. Arguably, the optimal approach could require the quantification of two cardiac biomarkers in the ED; a cardiac panel of hs-cTn and cMyC would hence provide the most benefit when implemented at the first blood draw to minimize the number of patients requiring ongoing observation and repeat blood testing. As chest pain and thereby suspected AMI is a very common complaint among patients presenting to EDs worldwide27,28—and responsible for ∼10–15 million attendances in the USA and Europe per year. Based on pragmatic assumptions, more than 1 million patients in the USA and Europe could benefit from earlier triage towards rule-out if the cMyC 0/1h-algorithm was used for initial assessment—this could translate into cost-savings exceeding €900 million/year (∼$1 billion). Dedicated cost-effectiveness analyses seem warranted.29

Study limitations

This study has several limitations: first, cMyC measurements were performed on a research assay and still require migration onto a clinical laboratory platform for automated use as part of chest pain triage. Although transition to a clinically available, central laboratory-based analyser is in progress, and the assay will be calibrated against the same recombinant protein used in the research assay, it is clearly necessary to confirm identical results and thresholds in future, prospective studies. Despite its size, use of an internal validation cohort, and other methodological strengths (central adjudication by two independent cardiologists according to the universal definition of MI), external validation in another large multicentre study is required. Second, as a prospective diagnostic study, we cannot exactly quantify the clinical benefit associated with the use of cMyC as an alternative or addition to hs-cTnT/I. Third, we cannot comment on the performance of the cMyC 0/1h-algorithm among patients with terminal kidney failure on renal replacement therapy, because such patients were excluded from this study. Fourth, the performance of the cMyC 0/1h-algorithm in cohorts with lower prevalence of MI, as frequently found in chest pain populations outside Europe, requires further investigation. Fifth, the use of hs-cTnT as the adjudicating biomarker might have biased results towards that assay and would require comparison in a cohort adjudicated using, e.g. a hs-cTnI assay. This might also be responsible for remarkably similar efficacy when comparing algorithms not based on the adjudicating biomarker (cMyC and hs-cTnI).

Conclusions

The cMyC 0/1h-algorithm provided excellent safety and identified a greater proportion of patients suitable for direct rule-out or rule-in based on a single measurement than the ESC 0/1h-algorithm using hs-cTnT/I.

Supplementary material

Supplementary material is available at European Heart Journal: Acute Cardiovascular Care online.

Acknowledgements

Members of APACE Investigators

Michael Freese1,2, Paul David Ratmann1,2, Alexandra Prepoudis1,2, Danielle M. Gualandro1,2, Nicolas Geigy2,3, Tobias Reichlin2,4, Katharina Rentsch5, Mario Maier1,2, Valentina Troester1,2, Juliane Gehrke1,2, Tania Coscia1,2, Noemi Glarner1,2, Hadrien Schoepfer1,2, Michael Buechi1,2, Joan Walter1,2, Ana Yufera Sanchez1,2, Christian Puelacher1,2, Jeanne du Fay de Lavallaz1,2, Alessandra Sanzione1,2, Ibrahim Schäfer1,2, Petra Hillinger1,2, Beatriz López6, Esther Rodriguez Adrada7, Piotr Muzyk2,8, Beata Morawiec2,8, Jiri Parenica2,9, Eva Ganovská2,9, Jens Lohrmann1,10, Andreas Buser11, Arnold von Eckardstein12, Roland Bingisser10, and Christian Nickel10

1Department of Cardiology and Cardiovascular Research Institute Basel (CRIB), University Hospital Basel, University of Basel, Switzerland; 2GREAT Network; Emergency Department, Kantonsspital Liestal, Liestal, Switzerland; 4Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; 5Department of Laboratory Medicine, University Hospital Basel, Basel, Switzerland; 6Servicio de Urgencias, Hospital Clínic, Barcelona, Spain; 7Emergency department, Hospital Clinico San Carlos, Madrid, Spain; 82nd Department of Cardiology, Medical University of Silesia, Zabrze, Poland; 9Department of Cardiology, University Hospital Brno, Brno, Czech Republic and Medical Faculty, Masaryk University, Brno, Czech Republic; 10Emergency Department, University Hospital Basel, University of Basel, Basel, Switzerland; 11Blood Transfusion Centre, Swiss Red Cross, Basel, Switzerland and Department of Hematology, University Hospital Basel, University of Basel, Basel, Switzerland; 12Department of Laboratory Medicine, University Hospital Zurich, Zurich, Switzerland.

Funding

Advantageous Predictors of Acute Coronary Syndrome Evaluation (APACE) was supported by research grants from the Swiss National Science Foundation, the European Union, the Swiss Heart Foundation, the University of Basel, the University Hospital Basel, Abbott, Brahms, Beckman Coulter, Quidel, Ortho Clinical Diagnostics, Roche, Singulex, and Siemens. This work was further supported by grants from the Medical Research Council (London, UK) (G1000737), Guy's and St Thomas' Charity (London, UK; R060701, R100404), British Heart Foundation (Birmingham, London; TG/15/1/31518, FS/15/13/31320), and the UK Department of Health through the National Institute for Health Research Biomedical Research Centre award to Guy’s & St Thomas’ National Health Service Foundation Trust. T.E.K. was funded through an NIHR clinical lectureship (CL-2019-17-006).

Conflict of interest: R.T. reports research support from the Swiss National Science Foundation (grant no. P300PB_167803), the Swiss Heart Foundation, the Swiss Society of Cardiology, the Cardiovascular Research Foundation Basel, the University of Basel, and the University Hospital Basel and speaker honoraria/consulting honoraria from Abbott, Amgen, Astra Zeneca, Roche, Siemens, Singulex, and Thermo Scientific BRAHMS. J.B. has received research grants from the University of Basel, the University Hospital of Basel and the Division of Internal Medicine, the Swiss Academy of Medical Sciences, and the Gottfried and Julia Bangerter-Rhyner-Foundation; and has received speaker honoraria and/or consulting honoraria from Siemens, Roche Diagnostics, Ortho Clinical Diagnostics, and Quidel Corporation. T.N. has received speaker honoraria and/or consulting honoraria from Beckman Coulter. L.K. has received a research grant from the University of Basel, the Swiss Academy of Medical Sciences, and the Gottfried and Julia Bangerter-Rhyner Foundation, as well as the Freiwillige Akademische Gesellschaft (FAG) Basel. M.R.G. has received research grants from the Swiss Heart Foundation and Swiss National Science Foundation (P400PM_180828) as well as speakers/consulting honoraria from Abbott, Ortho Diagnostic, Roche, and Siemens. C.M. has received research support from the Swiss National Science Foundation, the Swiss Heart Foundation, the Kommission für Technologie und Innovation, the University Hospital Basel, the University of Basel, Abbott, AstraZeneca, Beckman Coulter, Brahms, Idorsia, Novartis, Ortho Clinical Diagnostics, Quidel, Roche, Siemens, Singulex, Sphingotec, and has received speaker honoraria and/or consulting honoraria from Amgen, AstraZeneca, Boehringer Ingelheim, Bristol-Myers Squibb, Daiichi Sankyo, Idorsia, Osler, Novartis, Roche, Sanofi, Siemens, and Singulex, all paid to the institution. All the other authors have reported that they have no relationships relevant to the contents of this article to disclose. EMD Merck Millipore (Hayward, CA, USA) was contracted to undertake the analyses of cMyC on a fee-for-service basis and holds no commercial interest. M.M. is named as an inventor on a patent held by King’s College London for the detection of cardiac myosin–binding protein C as a biomarker of myocardial injury.

References

1

Ibanez
B
,
James
S
,
Agewall
S
,
Antunes
MJ
,
Bucciarelli-Ducci
C
,
Bueno
H
,
Caforio
ALP
,
Crea
F
,
Goudevenos
JA
,
Halvorsen
S
,
Hindricks
G
,
Kastrati
A
,
Lenzen
MJ
,
Prescott
E
,
Roffi
M
,
Valgimigli
M
,
Varenhorst
C
,
Vranckx
P
,
Widimský
P
;
ESC Scientific Document Group
.
2017 ESC guidelines for the management of acute myocardial infarction in patients presenting with ST-segment elevation
.
Eur Heart J
2018
;
39
:
119
177
.

2

Collet
J-P
,
Thiele
H
,
Barbato
E
,
Barthélémy
O
,
Bauersachs
J
,
Bhatt
DL
,
Dendale
P
,
Dorobantu
M
,
Edvardsen
T
,
Folliguet
T
,
Gale
CP
,
Gilard
M
,
Jobs
A
,
Jüni
P
,
Lambrinou
E
,
Lewis
BS
,
Mehilli
J
,
Meliga
E
,
Merkely
B
,
Mueller
C
,
Roffi
M
,
Rutten
FH
,
Sibbing
D
,
Siontis
GCM
; ESC Scientific Document Group.
2020 ESC guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation
.
Eur Heart J
2020
;
42
:
1289
1367
.

3

Wildi
K
,
Boeddinghaus
J
,
Nestelberger
T
,
Twerenbold
R
,
Badertscher
P
,
Wussler
D
,
Giménez
MR
,
Puelacher
C
,
Du Fay de Lavallaz
J
,
Dietsche
S
,
Walter
J
,
Kozhuharov
N
,
Morawiec
B
,
Miró
Ò
,
Javier Martin-Sanchez
F
,
Subramaniam
S
,
Geigy
N
,
Keller
DI
,
Reichlin
T
,
Mueller
C
;
APACE Investigators
.
Comparison of fourteen rule-out strategies for acute myocardial infarction
.
Int J Cardiol
2019
;
283
:
41
47
.

4

Boeddinghaus
J
,
Nestelberger
T
,
Badertscher
P
,
Twerenbold
R
,
Fitze
B
,
Wussler
D
,
Strebel
I
,
Rubini Giménez
M
,
Wildi
K
,
Puelacher
C
,
Du Fay de Lavallaz
J
,
Oehen
L
,
Walter
J
,
Miró
Ò
,
Martin-Sanchez
FJ
,
Morawiec
B
,
Potlukova
E
,
Keller
DI
,
Reichlin
T
,
Mueller
C
,
Sabti
Z
,
Freese
M
,
Stelzig
C
,
Shrestha
S
,
Schaerli
N
,
Kozhuharov
N
,
Flores
D
,
Lohrmann
J
,
Biskup
E
,
Kloos
W
,
Osswald
S
,
Mueller
D
,
Sazgary
L
,
López
B
,
Adrada
ER
,
Kawecki
D
,
Muzyk
P
,
Nowalany-Kozielska
E
,
Parenica
J
,
Ganovská
E
,
Meissner
K
,
Kulangara
C
,
Mahfouz
R
,
Hartmann
B
,
Ferel
I
,
Campodarve
I
,
Rentsch
K
,
von Eckardstein
A
,
Buser
A
,
Geigy
N
;
Additional APACE Investigators
.
Predicting acute myocardial infarction with a single blood draw
.
Clin Chem
2019
;
65
:
437
450
.

5

Boeddinghaus
J
,
Nestelberger
T
,
Twerenbold
R
et al.
High-sensitivity cardiac troponin I assay for early diagnosis of acute myocardial infarction
.
Clin Chem
2019
;
65
:
893
904
.

6

Twerenbold
R
,
Neumann
JT
,
Sörensen
NA
,
Ojeda
F
,
Karakas
M
,
Boeddinghaus
J
,
Nestelberger
T
,
Badertscher
P
,
Rubini Giménez
M
,
Puelacher
C
,
Wildi
K
,
Kozhuharov
N
,
Breitenbuecher
D
,
Biskup
E
,
Du Fay de Lavallaz
J
,
Flores
D
,
Wussler
D
,
Miró
Ò
,
Martín Sánchez
FJ
,
Morawiec
B
,
Parenica
J
,
Geigy
N
,
Keller
D
,
Zeller
T
,
Reichlin
T
,
Blankenberg
S
,
Westermann
D
,
Mueller
C.
Prospective validation of the 0/1-h algorithm for early diagnosis of myocardial infarction
.
J Am Coll Cardiol
2018
;
72
:
620
632
.

7

Reichlin
T
,
Hochholzer
W
,
Bassetti
S
,
Steuer
S
,
Stelzig
C
,
Hartwiger
S
,
Biedert
S
,
Schaub
N
,
Buerge
C
,
Potocki
M
,
Noveanu
M
,
Breidthardt
T
,
Twerenbold
R
,
Winkler
K
,
Bingisser
R
,
Mueller
C.
Early diagnosis of myocardial infarction with sensitive cardiac troponin assays - supplement
.
N Engl J Med
2009
;
361
:
858
867
.

8

Badertscher
P
,
Boeddinghaus
J
,
Twerenbold
R
,
Nestelberger
T
,
Wildi
K
,
Wussler
D
,
Schwarz
J
,
Puelacher
C
,
Rubini Giménez
M
,
Kozhuharov
N
,
Du Fay de Lavallaz
J
,
Cerminara
SE
,
Potlukova
E
,
Rentsch
K
,
Miró
Ò
,
López
B
,
Martin-Sanchez
FJ
,
Morawiec
B
,
Muzyk
P
,
Keller
D
,
Reichlin
T
,
Mueller
C;
APACE Investigators
.
Direct comparison of the 0/1h and 0/3h algorithms for early rule-out of acute myocardial infarction
.
Circulation
2018
;
137
:
2536
2538
.

9

Mueller
C
,
Giannitsis
E
,
Möckel
M
,
Huber
K
,
Mair
J
,
Plebani
M
,
Thygesen
K
,
Jaffe
AS
,
Lindahl
B
;
Biomarker Study Group of the ESC Acute Cardiovascular Care Association
.
Rapid rule out of acute myocardial infarction: novel biomarker-based strategies
.
Eur Heart J Acute Cardiovasc Care
2017
;
6
:
218
222
.

10

Chapman
AR
,
Hesse
K
,
Andrews
J
,
Ken Lee
K
,
Anand
A
,
Shah
AV
,
Sandeman
D
,
Ferry
AV
,
Jameson
J
,
Piya
S
,
Stewart
S
,
Marshall
L
,
Strachan
FE
,
Gray
A
,
Newby
DE
,
Mills
NL.
High-sensitivity cardiac troponin I and clinical risk scores in patients with suspected acute coronary syndrome
.
Circulation
2018
;
138
:
1654
1665
.

11

Baker
JO
,
Tyther
R
,
Liebetrau
C
,
Clark
J
,
Howarth
R
,
Patterson
T
,
Möllmann
H
,
Nef
H
,
Sicard
P
,
Kailey
B
,
Devaraj
R
,
Redwood
SR
,
Kunst
G
,
Weber
E
,
Marber
MS.
Cardiac myosin-binding protein C: a potential early biomarker of myocardial injury
.
Basic Res Cardiol
2015
;
110
:
1
14
.

12

Marjot
J
,
Kaier
TE
,
Martin
ED
,
Reji
S
,
Copeland
O
,
Iqbal
M
,
Goodson
B
,
Hamren
S
,
Harding
SE
,
Marber
MS.
Quantifying the release of biomarkers of myocardial necrosis from cardiac myocytes and intact myocardium
.
Clin Chem
2017
;
63
:
990
996
.

13

Kaier
TE
,
Anand
A
,
Shah
ASV
,
Mills
NL
,
Marber
M.
Temporal relationship between cardiac myosin-binding protein c and cardiac troponin I in type 1 myocardial infarction
.
Clin Chem
2016
;
62
:
1153
1155
.

14

Pickering
JW
,
Greenslade
JH
,
Cullen
L
,
Flaws
D
,
Parsonage
W
,
George
P
,
Worster
A
,
Kavsak
PA
,
Than
MP.
Validation of presentation and 3 h high-sensitivity troponin to rule-in and rule-out acute myocardial infarction
.
Heart Br Card Soc
2016
;
102
:
1270
1278
.

15

Twerenbold
R
,
Badertscher
P
,
Boeddinghaus
J
,
Nestelberger
T
,
Wildi
K
,
Rubini Gimenez
M
,
Miró
Ò
,
Martín-Sánchez
FJ
,
Reichlin
T
,
Mueller
C.
Effect of the FDA regulatory approach on the 0/1-h algorithm for rapid diagnosis of MI
.
J Am Coll Cardiol
2017
;
70
:
1532
1534
.

16

Kaier
TE
,
Twerenbold
R
,
Puelacher
C
,
Marjot
J
,
Imambaccus
N
,
Boeddinghaus
J
,
Nestelberger
T
,
Badertscher
P
,
Sabti
Z
,
Giménez
MR
,
Wildi
K
,
Hillinger
P
,
Grimm
K
,
Loeffel
S
,
Shrestha
S
,
Widmer
DF
,
Cupa
J
,
Kozhuharov
N
,
Miró
Ò
,
Martín-Sánchez
FJ
,
Morawiec
B
,
Rentsch
K
,
Lohrmann
J
,
Kloos
W
,
Osswald
S
,
Reichlin
T
,
Weber
E
,
Marber
M
,
Mueller
C.
Direct comparison of cardiac myosin-binding protein C with cardiac troponins for the early diagnosis of acute myocardial infarction
.
Circulation
2017
;
136
:
1495
1508
.

17

Rubini Gimenez
M
,
Twerenbold
R
,
Reichlin
T
,
Wildi
K
,
Haaf
P
,
Schaefer
M
,
Zellweger
C
,
Moehring
B
,
Stallone
F
,
Sou
SM
,
Mueller
M
,
Denhaerynck
K
,
Mosimann
T
,
Reiter
M
,
Meller
B
,
Freese
M
,
Stelzig
C
,
Klimmeck
I
,
Voegele
J
,
Hartmann
B
,
Rentsch
K
,
Osswald
S
,
Mueller
C.
Direct comparison of high-sensitivity-cardiac troponin I vs. T for the early diagnosis of acute myocardial infarction
.
Eur Heart J
2014
;
35
:
2303
2311
.

18

Reichlin
T
,
Hochholzer
W
,
Stelzig
C
,
Laule
K
,
Freidank
H
,
Morgenthaler
N
,
Bergmann
A
,
Potocki
M
,
Noveanu
M
,
Breidthardt
T
,
Christ
A
,
Boldanova
T
,
Merki
R
,
Schaub
N
,
Bingisser
R
,
Christ
M
,
Mueller
C.
Incremental value of copeptin for rapid rule out of acute myocardial infarction
.
J Am Coll Cardiol
2009
;
54
:
60
68
.

19

Haaf
P
,
Reichlin
T
,
Twerenbold
R
,
Hoeller
R
,
Rubini Gimenez
M
,
Zellweger
C
,
Moehring
B
,
Fischer
C
,
Meller
B
,
Wildi
K
,
Freese
M
,
Stelzig
C
,
Mosimann
T
,
Reiter
M
,
Mueller
M
,
Hochgruber
T
,
Sou
SM
,
Murray
K
,
Minners
J
,
Freidank
H
,
Osswald
S
,
Mueller
C.
Risk stratification in patients with acute chest pain using three high-sensitivity cardiac troponin assays
.
Eur Heart J
2014
;
35
:
365
375
.

20

Reiter
M
,
Twerenbold
R
,
Reichlin
T
,
Mueller
M
,
Hoeller
R
,
Moehring
B
,
Haaf
P
,
Wildi
K
,
Merk
S
,
Bernhard
D
,
Mueller
CZ
,
Freese
M
,
Freidank
H
,
Campodarve Botet
I
,
Mueller
C.
Heart-type fatty acid-binding protein in the early diagnosis of acute myocardial infarction
.
Heart
2013
;
99
:
708
714
.

21

Thygesen
K
,
Alpert
JS
,
Jaffe
AS
,
Chaitman
BR
,
Bax
JJ
,
Morrow
DA
,
White
HD
; Executive Group on behalf of the Joint European Society of Cardiology (ESC)/American College of Cardiology (ACC)/American Heart Association (AHA)/World Heart Federation (WHF) Task Force for the Universal Definition of Myocardial Infarction.
Fourth universal definition of myocardial infarction (2018)
.
J Am Coll Cardiol
2018
;
72
:
2231
2264
.

22

Marjot
J
,
Liebetrau
C
,
Goodson
RJ
,
Kaier
T
,
Weber
E
,
Heseltine
P
,
Marber
MS.
The development and application of a high-sensitivity immunoassay for cardiac myosin-binding protein C
.
Transl Res J Lab Clin Med
2016
;
170
:
17
25
.

23

Boeddinghaus
J
,
Nestelberger
T
,
Twerenbold
R
,
Wildi
K
,
Badertscher
P
,
Cupa
J
,
Bürge
T
,
Mächler
P
,
Corbière
S
,
Grimm
K
,
Giménez
MR
,
Puelacher
C
,
Shrestha
S
,
Flores Widmer
D
,
Fuhrmann
J
,
Hillinger
P
,
Sabti
Z
,
Honegger
U
,
Schaerli
N
,
Kozhuharov
N
,
Rentsch
K
,
Miró
Ò
,
López
B
,
Martin-Sanchez
FJ
,
Rodriguez-Adrada
E
,
Morawiec
B
,
Kawecki
D
,
Ganovská
E
,
Parenica
J
,
Lohrmann
J
,
Kloos
W
,
Buser
A
,
Geigy
N
,
Keller
D
,
Osswald
S
,
Reichlin
T
,
Mueller
C.
Direct comparison of 4 very early rule-out strategies for acute myocardial infarction using high-sensitivity cardiac troponin I
.
Circulation
2017
;
135
:
1597
1611
.

24

Kaier
TE
,
Stengaard
C
,
Marjot
J
,
Sørensen
JT
,
Alaour
B
,
Stavropoulou‐Tatla
S
,
Terkelsen
CJ
,
Williams
L
,
Thygesen
K
,
Weber
E
,
Marber
M
,
Bøtker
HE.
Cardiac myosin‐binding protein c to diagnose acute myocardial infarction in the pre‐hospital setting
.
J Am Heart Assoc
2019
;
8
: doi:.

25

Leisenring
W
,
Alonzo
T
,
Pepe
MS.
Comparisons of predictive values of binary medical diagnostic tests for paired designs
.
Biometrics
2000
;
56
:
345
351
.

26

Carlton
EW
,
Pickering
JW
,
Greenslade
J
,
Cullen
L
,
Than
M
,
Kendall
J
,
Body
R
,
Parsonage
WA
,
Khattab
A
,
Greaves
K.
Assessment of the 2016 National Institute for Health and Care Excellence high-sensitivity troponin rule-out strategy
.
Heart
2017
;
104
:
665
672
.

27

Marjot
J
,
Kaier
TE
,
Henderson
K
,
Hunter
L
,
Marber
MS
,
Perera
D.
A single centre prospective cohort study addressing the effect of a rule-in/rule-out troponin algorithm on routine clinical practice
.
Eur Heart J Acute Cardiovasc Care
2017
;
8
:
404
411
.

28

U.S. Department of Health and Human Services National Center for Health Statistics C for DC and P, U.S. Department of Health and Human Services
. National Hospital Ambulatory Medical Care Survey: 2012 Emergency Department Summary Tables. CDC.gov. http://www.cdc.gov/nchs/data/ahcd/nhamcs_emergency/2012_ed_web_tables.pdf (3 May 2017).

29

Ambavane
A
,
Lindahl
B
,
Giannitsis
E
,
Roiz
J
,
Mendivil
J
,
Frankenstein
L
,
Body
R
,
Christ
M
,
Bingisser
R
,
Alquezar
A
,
Mueller
C
;
TRAPID-AMI Investigators
.
Economic evaluation of the one-hour rule-out and rule-in algorithm for acute myocardial infarction using the high-sensitivity cardiac troponin T assay in the emergency department
.
PLoS One
2017
;
12
:
e0187662
.

Author notes

Thomas E. Kaier, Raphael Twerenbold contributed equally to the study.

The members of APACE Investigators are listed in the Acknowledgements section.

This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.

Supplementary data

Comments

0 Comments
Submit a comment
You have entered an invalid code
Thank you for submitting a comment on this article. Your comment will be reviewed and published at the journal's discretion. Please check for further notifications by email.