Abstract

Background

The presence of aortic and mitral disease in a patient who is not a suitable candidate for surgical correction poses significant challenges in the diagnostic workup as well as management plans. Percutaneous treatment can be staged to fix the aortic valve with transcatheter aortic valve implantation (TAVI) as a first step, followed by reassessment and percutaneous correction of mitral regurgitation (MR).

Case summary

A 65-year-old female with multiple co-morbidities presented with acute coronary syndrome and heart failure. She was diagnosed with three-vessel coronary artery disease and degenerative low-flow low-gradient severe aortic stenosis, along with severe degenerative MR with a left ventricular ejection fraction of 35%. Because of the high surgical risk, she underwent multi-vessel percutaneous coronary intervention with stenting. Transcatheter aortic valve implantation was done as a staged procedure, which partially improved her symptoms. Mitral regurgitation was not suitable for percutaneous mitral valve edge-to-edge repair. After a discussion by the heart team, she underwent transcatheter mitral valve implantation, for which the Tendyne mitral valve (Tendyne™; Abbott) was used through a transapical approach. There was no paravalvular leak, and the mean gradient across the valve was 2 mmHg. She was symptomatically better at follow-up and an echocardiogram showed a normally functioning aortic valve and Tendyne mitral valves.

Discussion

Transapical transcatheter mitral valve implantation using the Tendyne valve is a feasible option for patients with prior TAVI. This can be considered an alternative treatment for MR in patients who are not suitable for edge-to-edge mitral repair.

Learning points
  • The combination of degenerative aortic stenosis and mitral regurgitation (MR) is not uncommon.

  • If a patient is not a surgical candidate, aortic stenosis should be treated first by transcatheter aortic valve implantation, as it might reduce MR.

  • Transcatheter mitral valve implantation using the Tendyne valve is a feasible option for patients who are not suitable for mitral edge-to-edge repair.

Introduction

The incidence of degenerative multiple valvular heart disease is growing with increasing life expectancy. Age-related degeneration (41%) is the second most common cause of multiple valve disease after rheumatic fever (51%).1 Surgical intervention has been shown to improve survival significantly in symptomatic patients with multi-valvular disease.2 The presence of aortic and mitral disease in a patient who is not a suitable candidate for surgical correction poses significant challenges in the diagnostic workup as well as management plans. The combination of aortic stenosis and mitral regurgitation (MR) is not uncommon.1 The presence of significant aortic stenosis results in high mitral regurgitant volume at any given regurgitant orifice area because of an increased transmitral systolic gradient.2 If the patient is not a candidate for double valve correction, then percutaneous treatment can be staged to fix the aortic valve with transcatheter aortic valve implantation (TAVI) as a first step, followed by a reassessment and percutaneous correction of MR. The feasibility and clinical outcomes of transcatheter mitral valve implantation (TMVI) in patients who already had aortic valve prostheses are not well established. Here, we report a case of a female patient who underwent TAVI, followed by TMVI, for which the Tendyne™ mitral valve system (Abbott Vascular, Santa Clara, CA, USA) was used.

Summary figure

(A) Transoesophageal echocardiography view at 120° showing severe mitral regurgitation along with a transcatheter aortic valve implant in situ (yellow arrow). (B) Transoesophageal echocardiography image after the transcatheter mitral valve implantation showing a well-seated Tendyne valve (white arrow) without residual mitral regurgitation. (C) Three-dimensional zoom image of the mitral valve (atrial side) showing a well-seated Tendyne valve (white arrow). The frame of the transcatheter aortic valve implant is also seen (yellow arrow). (D) Still image of cardiac catheterization showing the Tendyne valve (white arrow) and transcatheter aortic valve implant (yellow arrow).

Case summary

A 65-year-old female (weight = 46 kg, body mass index = 21.2 kg/m2) is known to have diabetes mellitus, hypertension, hypothyroidism, peripheral vascular disease, and ischaemic heart disease. She presented to our hospital 4 years ago with acute coronary syndrome and heart failure. She was diagnosed with three-vessel coronary artery disease and degenerative low-flow low-gradient severe aortic stenosis, along with severe degenerative MR with a left ventricular (LV) ejection fraction of 35%. The cardiac surgeon declined coronary artery bypass grafting and double valve replacement for her because of the high risk of mortality and morbidity (EuroSCORE II 9.60%, STS score 8.84% risk of mortality). After a discussion by the heart team, she underwent multi-vessel percutaneous coronary intervention with stenting. Transcatheter aortic valve implantation was done as a staged procedure (26 mm Medtronic Evolut R valve), which partially improved her symptoms (Figure 1, see Supplementary material online, Video S1). Her LV ejection fraction also improved to 45%. She started developing worsening exertional dyspnoea and required multiple hospitalizations despite maximally tolerated guideline-directed medical therapy. Mitral regurgitation was assessed multiple times for transcatheter mitral valve edge-to-edge repair (TEER), but it was not done due to the high risk of functional mitral stenosis post repair, as the mitral valve area by three-dimensional planimetry was 1.9 cm2 with a mean gradient of 4 mmHg (Figure 2, see Supplementary material online, Videos S2 and S3). There was significant mitral annular calcification with calcified mitral apparatus. Mitral regurgitation originated mostly through medial and lateral scallops, and correction by TEER would require the use of more than one clip (high risk for functional stenosis).

Para-sternal long-axis view with colour Doppler showing degenerative changes in the mitral valve with severe mitral regurgitation. The transcatheter aortic valve implant is seen in the aortic position.
Figure 1

Para-sternal long-axis view with colour Doppler showing degenerative changes in the mitral valve with severe mitral regurgitation. The transcatheter aortic valve implant is seen in the aortic position.

(A) Transoesophageal echocardiography view at 120° showing severe mitral regurgitation along with transcatheter aortic valve implant in situ (yellow arrow). (B) A Three-dimensional zoom image of the mitral valve (en face view) showing restricted mitral opening.
Figure 2

(A) Transoesophageal echocardiography view at 120° showing severe mitral regurgitation along with transcatheter aortic valve implant in situ (yellow arrow). (B) A Three-dimensional zoom image of the mitral valve (en face view) showing restricted mitral opening.

She presented to the emergency department with exertional dyspnoea (New York Heart Association Functional Class III) and epigastric pain for 5 days. She was vitally stable with a pulse rate of 68 beats/min and a blood pressure of 130/58 mmHg. She was afebrile, and her oxygen saturation at room air was 95% on 2 L of oxygen through the nasal cannula. A cardiac examination revealed a soft first heart sound with a pan-systolic murmur at the apex, radiating to the axilla, and a soft S2 with a Grade II ejection systolic murmur at the base of the heart. Her electrocardiogram showed a normal sinus rhythm but with poor R-wave progression in the chest leads. The blood investigations showed a haemoglobin level of 9.1 g/dL (normal 12–16 g/dL), a serum creatinine level of 131 µmol/L (normal 40–90 µmol/L in females), and a troponin I level of 814 ng/L (normal <15.6 ng/L), and chest X-rays showed bilateral congestion with mild right pleural effusion. She was admitted with a diagnosis of non-ST-elevation myocardial infarction and acute decompensated heart failure. After initial management, she underwent coronary angiography, which showed severe in-stent restenosis of the right coronary artery stent, which was treated with a drug-eluted balloon angioplasty. Her echocardiography showed a normally functioning TAVI valve and severe MR of degenerative aetiology.

After the heart team discussion, she was worked up for TMVI, for which the Tendyne mitral valve (Tendyne™; Abbott) was used, as her MR was not suitable for percutaneous mitral valve edge-to-edge repair. Transcatheter mitral valve implantation was done using the Tendyne valve (∼22 months after TAVI) through the left anterolateral mini-thoracotomy under transoesophageal echocardiography guidance (Figures 35, see Supplementary material online, Videos S4–S6). There was no paravalvular leak, and the mean gradient across the valve was 2 mmHg. She was discharged on anticoagulation (warfarin for 6 months), a single antiplatelet (clopidogrel 75 mg daily), and heart failure therapy. On follow-up after 4 weeks, she was symptomatically better with pain at the thoracotomy site without any sign of infection. A follow-up (at 4 weeks) echocardiogram showed normally functioning TAVI and Tendyne valves. The LV ejection fraction dropped to 35–40%, which is expected after a correction of MR.

Transoesophageal echocardiography after the transcatheter mitral valve implantation showing a well-seated Tendyne valve (A, white arrow) without residual mitral regurgitation (B) on colour Doppler. A transcatheter aortic valve implant is also seen (yellow arrow).
Figure 3

Transoesophageal echocardiography after the transcatheter mitral valve implantation showing a well-seated Tendyne valve (A, white arrow) without residual mitral regurgitation (B) on colour Doppler. A transcatheter aortic valve implant is also seen (yellow arrow).

Three-dimensional zoom image of the mitral valve (atrial side) showing a well-seated Tendyne valve (white arrow). The frame of the transcatheter aortic valve implant is also seen (yellow arrow).
Figure 4

Three-dimensional zoom image of the mitral valve (atrial side) showing a well-seated Tendyne valve (white arrow). The frame of the transcatheter aortic valve implant is also seen (yellow arrow).

Cardiac catheterization still image showing the Tendyne valve (white arrow), transcatheter aortic valve implant (yellow arrow), and transoesophageal echocardiography probe (blue arrow).
Figure 5

Cardiac catheterization still image showing the Tendyne valve (white arrow), transcatheter aortic valve implant (yellow arrow), and transoesophageal echocardiography probe (blue arrow).

Discussion

Patients with mixed aortic and mitral valve disease show a rapid deterioration of symptoms and LV systolic function. In patients with low surgical risk, double valve replacement or repair is the treatment of choice. Transcatheter aortic valve implantation is becoming the standard of care for patients with moderate-to-high surgical risk.3 As the technology and experience of percutaneous valve repair and implantation are growing in clinical practice, it is not uncommon to encounter patients with MR with a prior history of TAVI. In patients undergoing TAVI, about one-fourth have Grade 2 MR, and ∼2–5% have severe MR.4 The implantation of the aortic valve, both percutaneously and surgically, has been shown to significantly decrease the severity of MR, although a minor percentage of patients showed a worsening of MR as well.5 Primary MR is less likely to improve than functional regurgitation.

Transcatheter aortic valve implantation has provided an opportunity to stage the percutaneous repair or replacement of concomitant mitral valve disease. The reported reduction in the severity of MR is likely multi-factorial and includes decreased transmitral gradients, decreased afterload, and remodelling of the LV cavity. The balloon-expandible aortic valve is associated with better MR reduction when compared with the self-expandible aortic valve post-TAVI. This effect is probably caused by an impairment of mitral leaflet motion, which is attributed to the self-expandible valve and a higher incidence of paravalvular leak.6 However, the newer generation of self-expandible TAVI valves might have different outcomes, and there is a gap in current data in this regard. The residual MR after TAVI is associated with worse short- and long-term prognoses.6,7

It is not well established whether the concomitant MR should be observed conservatively, percutaneously repaired simultaneously, or staged, as evidence is lacking in this regard. The management of MR is thus individualized based on symptoms, suitable anatomy, procedural risks, and local expertise.8 Transcatheter mitral valve edge-to-edge repair is a safe and effective alternative method for the correction of primary and secondary MR in patients who are considered unsuitable for surgical correction.9 Currently, the MitraClip (Abbott) is widely used in TEER procedures, both in primary and in secondary MR. However, the use of TEER in patients with prior TAVI showed less favourable outcomes in terms of residual MR and cardiac output.10 These outcomes are probably caused by an altered mitral valve anatomy, which is attributed to a prior TAVI procedure.

Transcatheter mitral valve implantation has emerged as a treatment option for severe symptomatic MR for those who are either failed or unsuitable for percutaneous repair.11–13 The Tendyne™ mitral valve system (Abbott Vascular) is implanted transapically without the need for conducting a bypass. The valve is anchored to the epicardial pad via a chord. The feasibility of TMVI by using the Tendyne mitral valve in patients with prior surgical transcatheter aortic valve replacement is not well established because of limited data. The risk of left ventricular outflow tract (LVOT) obstruction is probably high because of post-TAVI mitral anatomy, LV hypertrophy, and a smaller LV cavity in these patients. A recently published small series showed that the Tendyne system is a safe and feasible treatment option for MR in patients with prior TAVI procedures.14 Our patient had low-flow, low-gradient severe aortic stenosis and a moderate-to-severe degenerative MR. She underwent TAVI and showed improvement in LV ejection fraction. She remained symptomatic with heart failure admissions despite optimized guideline-directed medical therapy. After a heart team discussion, she underwent successful TMVI, for which the Tendyne valve was used, following which there was a complete resolution of regurgitation.

Conclusion

In summary, transapical transcatheter mitral valve implantation using the Tendyne valve is a feasible option for patients with prior TAVI. This can be considered an alternative treatment for MR in such patients who are not suitable for edge-to-edge mitral repair.

Lead author biography

graphicDr Muhammad Azam Shah is a qualified cardiologist with a subspecialized qualification in echocardiography and cardiac computed tomography with a keen interest in the area of research and development. After obtaining cardiology fellowship from Pakistan, he joined King Fahad Medical City, Riyadh, Saudi Arabia, where he underwent subspecialty training in advanced cardiac imaging. He is a consultant cardiologist and works in the imaging section.

Supplementary material

Supplementary material is available at European Heart Journal – Case Reports online.

Consent: The authors confirm that written consent for the submission and publication of this case report, including images and associated text, has been obtained from the patient and family in line with COPE guidance.

Funding: None declared.

Data availability

The data underlying this article are available in the article and its online Supplementary material.

References

1

Iung
B
,
Baron
G
,
Tornos
P
,
Gohlke-Bärwolf
C
,
Butchart
EG
,
Vahanian
A
.
Valvular heart disease in the community: a European experience
.
Curr Probl Cardiol
2007
;
32
:
609
661
.

2

Husso
A
,
Riekkinen
T
,
Rissanen
A
,
Ollila
J
,
Valtola
A
.
Combined mitral and aortic valve surgery: 17-year experience in a single center
.
Scand J Surg
2021
;
110
:
533
541
.

3

Otto
CM
,
Nishimura
RA
,
Bonow
RO
,
Carabello
BA
,
Rwin
JP
,
Gentile
F
, et al.
2020 ACC/AHA guideline for the management of patients with valvular heart disease: executive summary: a report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines
.
Circulation
2021
;
143
:
E35
E71
.

4

Masson
JB
,
Forcillo
J
.
Mixed-valve disease: management of patients with aortic stenosis and mitral regurgitation: thresholds for surgery versus percutaneous therapies
.
US Cardiol Rev
2021
;
15
:
e26
..

5

Barbanti
M
,
Webb
JG
,
Hahn
RT
,
Feldman
T
,
Boone
RH
,
Smith
CR
, et al.
Impact of preoperative moderate/severe mitral regurgitation on 2-year outcome after transcatheter and surgical aortic valve replacement insight from the placement of aortic transcatheter valve (PARTNER) trial cohort A
.
Circulation
2013
;
128
:
2776
2784
.

6

Nombela-Franco
L
,
Eltchaninoff
H
,
Zahn
R
,
Testa
L
,
Leon
MB
,
Trillo-Nouche
R
, et al.
Clinical impact and evolution of mitral regurgitation following transcatheter aortic valve replacement: a meta-analysis
.
Heart
2015
;
101
:
1395
1405
.

7

Mauri
V
,
Körber
MI
,
Kuhn
E
,
Schmidt
T
,
Frerker
C
,
Wahlers
T
, et al.
Prognosis of persistent mitral regurgitation in patients undergoing transcatheter aortic valve replacement
.
Clin Res Cardiol
2020
;
109
:
1261
1270
.

8

Stähli
BE
,
Reinthaler
M
,
Leistner
DM
,
Landmesser
U
,
Lauten
A
.
Transcatheter aortic valve replacement and concomitant mitral regurgitation
.
Front Cardiovasc Med
2018
;
5
:
74
.

9

Stone
GW
,
Lindenfeld
JA
,
Abraham
WT
,
Kar
S
,
Lim
DS
,
Mishell
JM
, et al.
Transcatheter mitral-valve repair in patients with heart failure
.
N Engl J Med
2018
;
379
:
2307
2318
.

10

Patzelt
J
,
Ulrich
M
,
Becker
A
,
Müller
KAL
,
Jorbenadze
R
,
Droppa
M
, et al.
Previous TAVR in patients undergoing percutaneous edge-to-edge mitral valve repair (PMVR) affects improvement of MR
.
PLoS One
2018
;
13
:
e0205930
.

11

Beller
JP
,
Rogers
JH
,
Thourani
VH
,
Ailawadi
G
.
Early clinical results with the Tendyne transcatheter mitral valve replacement system
.
Ann Cardiothorac Surg
2018
;
7
:
776
779
.

12

Feldman
T
,
Kar
S
,
Rinaldi
M
,
Fail
P
,
Hermiller
J
,
Smalling
R
, et al.
Percutaneous mitral repair with the MitraClip system: safety and midterm durability in the initial EVEREST (Endovascular Valve Edge-to-Edge REpair Study) cohort
.
J Am Coll Cardiol
2009
;
54
:
686
694
.

13

Russo
G
,
Gennari
M
,
Gavazzoni
M
,
Pedicino
D
,
Pozzoli
A
,
Taramasso
M
, et al.
Transcatheter mitral valve implantation: current status and future perspectives
.
Circ Cardiovasc Interv
2021
;
14
:
967
978
.

14

Taramasso
M
,
Sorajja
P
,
Dahle
G
,
Dumonteil
N
,
Schäfer
L
,
Modine
T
, et al.
Transapical transcatheter mitral valve implantation in patients with prior aortic valve replacement: a feasibility report
.
EuroIntervention
2021
;
17
:
257
259
.

Author notes

Conflict of interest: None declared.

This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact [email protected]
Handling Editor: Giulio Russo
Giulio Russo
Handling Editor
Search for other works by this author on:

Editor: Masahiko Asami,
Masahiko Asami
Editor
Search for other works by this author on:
Andrew Harris,
Andrew Harris
Editor
Search for other works by this author on:
Ralph Mark Louis Neijehuis
Ralph Mark Louis Neijehuis
Editor
Search for other works by this author on:

Supplementary data

Comments

0 Comments
Submit a comment
You have entered an invalid code
Thank you for submitting a comment on this article. Your comment will be reviewed and published at the journal's discretion. Please check for further notifications by email.